Max working pressure 1 6 Mpa PVC Cooling Tower Drift Eliminator

Just fill in the form below, click submit, you will get the price list, and we will contact you within one working day. Please also feel free to contact us via email or phone. (* is required).

  • DE-120 Blade Drift Eliminator - Cooling Tower Depot

    2010-4-14 · Ò DE-120 blade type drift eliminator designed to remove entrained water droplets from the leaving air stream at minimum pressure losses in either counter-flow or cross-flow cooling towers. 2. Material of Construction : A. General The drift modules shall be fabricated from rigid, corrugated PVC sheets that are conducive to cooling water and UV ...

    Get Price
  • DE-97 Blade Drift Eliminator - m.coolingtowerdepot.com

    2010-4-14 · DE-97 Blade Drift Eliminator BLADE TYPE D. E. PRODUCT SPECIFICATION The media is to be manufactured by Brentwood Industries, or equal and will meet the following specifications: 1. Scope: ACCU-PAC DE- blade type drift eliminator designed to remove entrained water droplets from the leaving air stream at minimum pressure losses in either counter-flow

    Get Price
  • Cooling Tower Thermal Design Manual - Sharif

    2007-11-13 · Cooling Tower Thermal Design Manual Air Density: 0.0714 Lb/ft3 Air Specific Volume: 14.3309 ft3/Lb dry air Air Enthalpy: 46.3774 Btu/Lb dry air Download the example file (exe1_1.zip) This file covers the examples of 1-1 through 1-4. Example 1-2.

    Get Price
  • Plastic Cooling Tower atomizing spray nozzle - Coowor.com

    Understand Plastic Cooling Tower atomizing spray nozzle information in Xinxiang JIAHUI RFP Environmental Equipment Co.,Ltd company, and quickly obtain the latest quotation, select more quality Cooling Tower manufacturers and suppliers on coowor.com

    Get Price
  • PVC Cooling Tower Nozzles

    pvc fills cooling tower Cooling tower fills of size 600 x 300 x 150 mm ( 1 CFT ) and 600 x 150 x 150 mm ( 1/2 CFT ) made of corrugated virging quality PVC film duly vacuum formed and edge folded for extended service life. Available in blue and black colors for cooling tower of FRP induced draft counter flow type and cross flow type.

    Get Price
  • SPL Evaporative Condensers - Glaciem Cooling

    2020-7-10 · 6 Patented Drift Eliminator SPL’s detachable drift eliminator is made from specially de-signed non-corroding PVC material. The patented eliminators comply with AS/NZS 3666.1:20116 with a maximum drift loss of 0.001%. Eliminators are designed for ease of maintenance making them extremely easy to clean. Pressurized Water Distribution System

    Get Price
  • Cooling Tower Spare Parts - Deck Spray Nozzle

    Manufacturer of Cooling Tower Spare Parts - Deck Spray Nozzle, FRP Louvers, Cooling Tower Flower Nozzle and Cooling Tower Nozzle offered by Banas Cooling Tower Corporation, Palanpur, Gujarat.

    Get Price
  • GHM Series Cross Flow Closed Water Cooling Towers - Buy ...

    WORKING THEORY. GHM series belong to induced draft type cross flow cooling towers. During the working process, dry cool air is inlet through wide louvers on one side of the tower, then directed through the heat exchange coils and wet deck fills across the spray water, becoming wet hot air, eventually induced draught out of the tower into the atmosphere by the fans on the top.

    Get Price
  • Lbcm Counter Flow Induced Draft Cooling Tower - Buy ...

    Lbcm Counter Flow Induced Draft Cooling Tower , Find Complete Details about Lbcm Counter Flow Induced Draft Cooling Tower,Cooling Tower,Frp Cooling Tower,Mini Cooling Tower from Cooling Tower Supplier or Manufacturer-Tianjin Latino Environmental Technology Co., Ltd.

    Get Price
  • Experimental Study on Inlet Air Cooling by Water Spray

    2014-12-18 · pressure was measured using a pressure sensor (P1600-3000, Pace Scientific Inc.) with a working range of 0-20.6 MPA and accuracy of 1% of full scale. Water flow rate was measured using the “bucket and stopwatch” technique in separate calibration …

    Get Price
  • SPL Evaporative Condensers - Glaciem Cooling

    2020-7-10 · 6 Patented Drift Eliminator SPL’s detachable drift eliminator is made from specially de-signed non-corroding PVC material. The patented eliminators comply with AS/NZS 3666.1:20116 with a maximum drift loss of 0.001%. Eliminators are designed for ease of maintenance making them extremely easy to clean. Pressurized Water Distribution System

    Get Price
  • Cooling Towers - Cooling Tower Manufacturer from

    Manufacturer of Cooling Towers - Cooling Tower, Water Cooling Towers, Cooling Tower 10TR and Cooling Tower 15TR offered by Jet Cooling Towers, Hyderabad, Telangana.

    Get Price
  • Experimental Study on Inlet Air Cooling by Water Spray

    2014-12-18 · pressure was measured using a pressure sensor (P1600-3000, Pace Scientific Inc.) with a working range of 0-20.6 MPA and accuracy of 1% of full scale. Water flow rate was measured using the “bucket and stopwatch” technique in separate calibration …

    Get Price
  • Guide to Thread and Connector Working Pressures

    2017-6-14 · MAX. WORKING PRESSURE mm bar psi M14 x 1,5-14 700 10150 M18 x 1,5-18 700 10150 M22 x 1,5-22 600 8700 M24 x 1,5-24 500 7250 M30 x 1,5-30 420 6000 M33 x 1,5-33 350 5100 M36 x 1,5-36 280 4060 M42 x 1,5-42 280 4060. CONNECTING PARTNERSHIPS Page 421 Filters Intro Hose Couplings Adaptors Accessories Technical Guide to Thread and Connector Working ...

    Get Price
  • Safety factor (bursting pressure working pressure ...

    Safety factor (bursting pressure working pressure) Water hoses with maximum working pressure 1 MPa (10 bar). Hose for other fluids, water slurries, solid materials and water with working pressure above 1 MPa (10 bar). Hoses for compressed air and other gases. Hoses for fluids that may change into gases during pressure drop.

    Get Price
  • Components of Cooling Towers - Tube Settler

    Components of Cooling Towers. With the help of our experienced engineers, we are able to manufacture and supply a broad spectrum of Cooling Tower Profiles. Our offered range is manufactured employing latest machines and advanced technology following industry standards & norms. All our products are widely acknowledged in market for their fine ...

    Get Price
  • How To: Calculate The Maximum Allowable Working

    2021-8-26 · E = Efficiency of longitudinal welded joints or of ligaments between openings, whichever is lower (the values allowed for E are listed in PG-27.4, note 1) page 11. e = Thickness factor for expanded tube ends (mm) (see PG-27.4, note 4) page 11. P = Maximum allowable working pressure “Gauge Pressure” (MPa) (see PG-21, refers to gauge pressure)

    Get Price
  • Marley Aquatower Cooling Tower - usermanual.wiki

    2021-8-25 · parts work together to provide you the greatest total performance. And because we design specifically for cooling towers, all our components will provide many years of service with minimal maintenance. Every Aquatower cooling tower carries a full one-year warranty. The Aquatower you buy from us will work on your job or we’ll make it right.

    Get Price
  • Heat Exchangers in Coimbatore - Manufacturers and ...

    Find Heat Exchangers manufacturers, Heat Exchangers suppliers, exporters, wholesalers and distributors in Coimbatore Tamil nadu India - List of Heat Exchangers selling companies from Coimbatore with catalogs, phone numbers, addresses & prices for …

    Get Price
  • Vinyl uPVC Pressure Pipes (As per IS: 4985-2000)

    2020-6-3 · Vinyl uPVC Pipes Pressure & Non Pressure - are manufactured in accordance with IS:4985 covering a complete range from 20 mm to 315 mm. They are available in pressure ratings of 2.5, 4, 6, 8 & 10 kgf/sq. cm as defined in IS:4985.

    Get Price
  • Guide to Thread and Connector Working Pressures

    2017-6-14 · MAX. WORKING PRESSURE mm bar psi M14 x 1,5-14 700 10150 M18 x 1,5-18 700 10150 M22 x 1,5-22 600 8700 M24 x 1,5-24 500 7250 M30 x 1,5-30 420 6000 M33 x 1,5-33 350 5100 M36 x 1,5-36 280 4060 M42 x 1,5-42 280 4060. CONNECTING PARTNERSHIPS Page 421 Filters Intro Hose Couplings Adaptors Accessories Technical Guide to Thread and Connector Working ...

    Get Price
  • Energy assessment and external circulation design for LNG ...

    The LPN 2 of about 0.13 MPa from the air separation rectification tower passes through HE1, HE2 and Compr3 to reach a pressure of 0.6 MPa. It then mixes with CN 2 and is pressurized again through HE1, HE2 and Compr2. This process is repeated until the pressure increases to 6 MPa, and then it enters HE3 to be cooled to 120 K.

    Get Price
  • How To: Calculate The Maximum Allowable Working

    2021-8-26 · E = Efficiency of longitudinal welded joints or of ligaments between openings, whichever is lower (the values allowed for E are listed in PG-27.4, note 1) page 11. e = Thickness factor for expanded tube ends (mm) (see PG-27.4, note 4) page 11. P = Maximum allowable working pressure “Gauge Pressure” (MPa) (see PG-21, refers to gauge pressure)

    Get Price
  • Safety factor (bursting pressure working pressure ...

    Safety factor (bursting pressure working pressure) Water hoses with maximum working pressure 1 MPa (10 bar). Hose for other fluids, water slurries, solid materials and water with working pressure above 1 MPa (10 bar). Hoses for compressed air and other gases. Hoses for fluids that may change into gases during pressure drop.

    Get Price
  • SPL Evaporative Condensers - Glaciem Cooling

    2020-7-10 · 6 Patented Drift Eliminator SPL’s detachable drift eliminator is made from specially de-signed non-corroding PVC material. The patented eliminators comply with AS/NZS 3666.1:20116 with a maximum drift loss of 0.001%. Eliminators are designed for ease of maintenance making them extremely easy to clean. Pressurized Water Distribution System

    Get Price
  • Marley Aquatower Cooling Tower - usermanual.wiki

    2021-8-25 · parts work together to provide you the greatest total performance. And because we design specifically for cooling towers, all our components will provide many years of service with minimal maintenance. Every Aquatower cooling tower carries a full one-year warranty. The Aquatower you buy from us will work on your job or we’ll make it right.

    Get Price
  • Cooling Towers - Cooling Tower Manufacturer from

    Manufacturer of Cooling Towers - Cooling Tower, Water Cooling Towers, Cooling Tower 10TR and Cooling Tower 15TR offered by Jet Cooling Towers, Hyderabad, Telangana.

    Get Price
  • Heat Exchangers in Coimbatore - Manufacturers and ...

    Find Heat Exchangers manufacturers, Heat Exchangers suppliers, exporters, wholesalers and distributors in Coimbatore Tamil nadu India - List of Heat Exchangers selling companies from Coimbatore with catalogs, phone numbers, addresses & prices for Heat Exchangers.

    Get Price
  • Components of Cooling Towers - Tube Settler

    Components of Cooling Towers. With the help of our experienced engineers, we are able to manufacture and supply a broad spectrum of Cooling Tower Profiles. Our offered range is manufactured employing latest machines and advanced technology following industry standards & norms. All our products are widely acknowledged in market for their fine ...

    Get Price
  • Pressure Drop Online-Calculator

    2017-9-28 · Pressure Drop Online-Calculator Calculation of pressure drops of flowing liquids and gases in pipes and pipe elements (laminar and turbulent flow). Note: Calculations are possible only, if Javascript is activated in your browser. Pressure Drop Online-Calculator for small mobiles. This version is usable for browsers without Javascript also.

    Get Price
  • COOLDECK

    COOLDECK’s drift eliminators are specifically designed to achieve maximum drift removal efficiency in both crossflow and counterflow tower applications with various product options available to minimize pressure drop, drift loss, cost, or a combination of all three.

    Get Price
  • Humidity and Temperature Sensors - Air Velocity and ...

    Working Temperature: 40 to 120 deg C: ... Cooling Tower PVC Drift Eliminator Manufacturer Delhi India ... 1900-1 Dwyer Series Compact Low Differential Pressure Switch Range 0.40-1.6' W.C. view all.. Flexible Ducts Wholesale Suppliers India ...

    Get Price
  • Marley NC - SPX Cooling Towers

    Marley towers are the only package cooling towers tested per CTI ATC-128 test code by third-party CTI-licensed test agents and certified acoustical engineers. NC sound levels are independently verified to meet published sound levels. Lowest Drift Rates. Lower drift means less water escapes the tower, providing cleaner surroundings.

    Get Price
  • Pressure Gages wholesaler & Wholesale Dealers in ...

    Cooling Tower PVC Fills Manufacture From India; ... PVC Drift Eliminator - Polyvinyl Chloride Drift Eliminator Manufacturer-D.P.Engineers; ... Vacuum range max. pressure is 30 psig.Thermal Effect0.05% FS Degree C.Process Connection1/4' male NPT.Power Requirements9 V alkaline battery, included, user replaceable.Auto Shut Off20 minute auto shut ...

    Get Price
  • Aquatower engineering data - Cooling Towers and

    2021-8-11 · Every Aquatower cooling tower carries a full one-year warranty. The Aquatower you buy from us will work on your job or . we’ll make it right. Your warranty includes thermal performance and every component of the tower. The SPX Cooling Technologies warranty is your assurance of performance—for a …

    Get Price
  • Cooling Tower

    2019-2-24 · 140990105008_cooling tower - View presentation slides online. cooling tower types

    Get Price
  • Performance analysis of cooling tower using desiccant ...

    2019-12-4 · Cooling towers are one of the biggest heat and mass transfer devices that are in widespread use. In this work, the cooling tower model has been fabricated and silica gel mesh (SGM) column is installed at the inlet of the cooling tower. Experiments have been performed for three different modes namely with 0, 1 and 2 silica gel mesh with the subcases of varying air velocity and inlet water ...

    Get Price
  • Comparative study on the cooling characteristics of high ...

    2016-5-15 · As shown in Fig. 1(b), the studied HNDWCT has an air inlet height of 9 m, an air outlet height of 130 m and an air outlet diameter of 60.081 m. The fill of this HNDWCT is the S-wave fill, with a depth of 1.5 m, a total water drenching area of 6000 m 2 and a bottom height of 13.2 m. Beneath the fill, 88 sets of water collecting units are set up to collect falling water droplets, whose local ...

    Get Price
  • SPX Cooling – New York – Marley Cooling Towers

    2018-11-5 · Starting November 5, 2018, you can find us at:50 South Buckhout Street, Suite 204Irvington, NY 10533. Our dependable team of experts are passionate about their work and enjoy working for you. We are committed to designing and delivering high …

    Get Price
  • OPERATION & SERVICE MANUAL FOR NEK-A

    Cooling systems. It is suitable to work with following fluids: R134a, R404A, R407C, R507A and R717 (NH3). For other refrigerants (fluids) please contact our Technical Department for advice. Test pressure for the condensers is 31.5 bar. Figure 1 1. Drift eliminator 2. Heat exchange coil 3. GFRP casing 4. Union between two bodies with seal joint 5.

    Get Price